規格 | 容量 | 輸入電源 | 輸 出電壓 | 重量(kg) | |||
相數 | (V) | (A) | (V) | (A) | |||
2/220 | 2 | 1 | 220 | 10 | 0-250 | 8 | 14 |
3/220 | 3 | 1 | 220 | 15 | 0-250 | 12 | 16 |
5/220 | 5 | 1 | 220 | 25 | 0-250 | 20 | 18 |
10/220 | 10 | 1 | 220 | 50 | 0-250 | 40 | 80 |
15/380 | 15 | 2 | 380 | 37.5 | 0-430 | 34.8 | 90 |
20/380 | 20 | 2 | 380 | 50 | 0-430 | 46.5 | 100 |
25/380 | 25 | 2 | 380 | 62.5 | 0-430 | 58.1 | 120 |
30/380 | 30 | 2 | 380 | 75 | 0-430 | 69.7 | 140 |
50/380 | 50 | 2 | 380 | 125 | 0-430 | 116.2 | 160 |
100/380 | 100 | 2 | 380 | 250 | 0-430 | 232.5 | 250 |
說明:如有特殊參數要求,可按用戶的技術參數進行設計制作。 |
規格 | 容量 kVA | 低壓側 | 高壓側 | 高壓側(交直流變壓器) | 測量變比 | 60分鐘溫升℃ | 阻抗電壓% | 空載電流 % | 質量 kg | |||
電壓 V | 電流 A | 交流輸出 | 直流輸出 | |||||||||
電壓kV | 電流 | 電壓kV | 電流 | |||||||||
1.5/50 | 1.5 | 200 | 7.5 | 50 | 30 | 70 | 21.4 | 500 | 50 | 10 | <4 | 19.5 |
3/50 | 3 | 200 | 15 | 50 | 60 | 70 | 42.9 | 500 | 50 | 10 | <4 | 27 |
5/50 | 5 | 200 | 25 | 50 | 100 | 70 | 71.4 | 500 | 50 | 10 | <4 | 52 |
10/50 | 10 | 200 | 50 | 50 | 200 | 70 | 142.9 | 500 | 50 | 10 | <4 | 80 |
15/50 | 15 | 400 | 37.5 | 50 | 300 | 70 | 214.3 | 500 | 50 | 8 | <4 | 120 |
20/50 | 20 | 400 | 50 | 50 | 400 | 70 | 285.7 | 500 | 50 | 8 | <4 | 140 |
30/50 | 30 | 400 | 75 | 50 | 600 | 70 | 428.6 | 500 | 50 | 8 | <4 | 155 |
50/50 | 50 | 400 | 125 | 50 | 1000 | 70 | 714.3 | 500 | 50 | 8 | <4 | 184 |
10/100 | 10 | 200 | 50 | 100 | 100 | 140 | 71.4 | 1000 | 50 | 10 | <4 | 135 |
15/100 | 15 | 400 | 37.5 | 100 | 150 | 140 | 107.1 | 1000 | 50 | 8 | <4 | 150 |
20/100 | 20 | 400 | 50 | 100 | 200 | 140 | 142.9 | 1000 | 50 | 8 | <4 | 215 |
30/100 | 30 | 400 | 75 | 100 | 300 | 140 | 214.3 | 1000 | 50 | 8 | <4 | 250 |
50/100 | 50 | 400 | 125 | 100 | 500 | 140 | 357.1 | 1000 | 50 | 8 | <4 | 290 |
10/150 | 10 | 200 | 50 | 100 | 66.7 | 140 | 47.6 | 1500 | 50 | 10 | <4 | 180 |
15/150 | 15 | 400 | 37.5 | 150 | 100 | 210 | 71.4 | 1500 | 50 | 8 | <4 | 200 |
20/150 | 30 | 400 | 50 | 150 | 133.3 | 210 | 95.2 | 1500 | 50 | 8 | <4 | 220 |
30/150 | 30 | 400 | 75 | 150 | 200 | 210 | 142.9 | 1500 | 50 | 8 | <4 | 280 |
50/150 | 50 | 400 | 125 | 150 | 333.3 | 210 | 238.1 | 1500 | 50 | 8 | <4 | 340 |
說明:如有特殊參數要求,可按用戶的技術參數進行設計制作。 上表的重量以油浸式試驗變壓器為例,干式試驗變壓器和充氣式試驗變壓器稍有不同。 |
一.概述
HZ-C05系列吸油煙機空氣性能試驗裝置是根據GB/T17713-2011《吸油煙機》GB/T14806-2003 《家用和類似用途的交流換氣扇及其調速器》等標準研發制造的風量測量系統。該空氣性能試驗裝置主要針對GB/T17713-2011《吸油煙機》標準附錄C的“外排式吸油煙機空氣性能試驗裝置”,該裝置只能針對“外排式吸油煙機”做測試,不能用于“循環式吸油煙機”測試。
其基本測試原理是:在測試風洞中模擬試品的實際工作狀態,變換出風口的孔板直徑,然后測出風口的每次靜壓值,再由標準公式計算出此時對應的的流量系數及風量等參數。
該裝置采用計算機自動測控方式,只需人工安裝試品和更換孔板,測試一臺試品全過程只需十分鐘。可以測繪靜壓與風量、風量與轉速、電流、功率、效率等對應曲線。具有方便快捷、穩定可靠、重現性好等特點。滿足相關產品的科研和生產過程中測試使用。
產品名稱:吸油煙機空氣性能試驗裝置
型號規格:HZ-C05
標準依據: GB/T 17713-2011、GB/T14806-2003等相關產品標準。
適用產品: 吸油煙機、管道式換氣扇、送風機等。
性能及特點要求:
1) 由電腦及其周邊設備實現自動測試、演算及數據輸出,圖形顯示打印測試結果。人機對話操作簡單,精度高,省時省力。
2) 測試項目:P-Q特性(流量與靜壓的關系)、Q-η特性(流量與效率的關系)、同步測定被測體的轉速、電流、功率。
二.總體方案
本方案不包括試驗室建筑結構部分,該部分由用戶根據標準要求自行建造。
1.試驗室一般要求
尺寸:3500(寬)×5000(長)×2800(高)mm以上。
墻壁:光滑平整,沒有影響氣流的開孔(空調開孔不應直吹)。
地面:應保持地面平整。
溫濕度:風量測量時試驗室空氣溫度為 20℃±5℃、濕度為 30%-80%。
大氣壓:海拔不超過1000米的普通大氣環境。
2.測試系統
主要構成:風量測試風洞、出風口調節孔板、測控電氣柜(包括變頻電源、電參數測量儀、壓力變送器、轉速表等)、品牌電腦、打印機、試品升降臺、試品安裝法蘭及測試風管。
系統功能:由計算機提示輸入試品參數和測試相關數據后,便可實現全部自動測控功能:包括、風量測量;電壓、電流、功率測量;轉速測量、溫濕度和大氣壓測量、測試過程提示、數據表格、相關曲線等。
3.配電要求:用戶須提供獨立的配電開關,單相二線加地線供電:
AC 220V,50Hz 最大容量:2KVA
德國PTL壓痕試驗裝置 IEC60811壓痕試驗儀供應進口壓痕測試裝置
PTL壓痕裝置用于插頭的插腳絕緣套管和直徑達20mm
電線和電纜在200°C負載達11.5N的壓力測試,根據IEC 60811-3-1 / 1985 + 表 May 1986&8.1.3
和 & 8.2.3 圖. 1, EN 60811-3-1 / 草稿 1994&8.1.3
and &8.2.3 圖. 1, VDE 0473 811-3-1 部分/ 草稿 1995-01 & 8.1.3
and & 8.2.3圖. 1
Standard outfit:
1 base plate, dimensions of the floor space 100 mm x 150 mm,
1 stand, with support, with plane sample bearing surface,
1 testing frame, mass including blade 25,5 g, exerted load 0,25 N,
1 straight blade, hardened and ground, 0,7 +0,01 mm thick, exchangeable,
1 load carrier, mass 25,5 g, for fitting the load weights, exerted load 0,25 N,
1 set of load weights, to load the sample with forces from 0,5 N to 11,5 N in steps of 0,01 N.
Design:base plate and small weight pieces of aluminum, all other parts of steel browned or nickel plated, bearing surface of the support ground, total height approx.
270 mm with sample diameter 20 mm, Article No.: T 13.10
alternative:
PTL Indentation Device 20
as above, but for simultaneous testing of 2 samples, with 2 testing frames, 2 load carriers and 2 sets of load weights, stand with bearing support T-shaped,
Article No.: T 13.20
Rounded blade with radius 6 mm according to IEC 60884-1 / 1994 Fig. 29:on request
PTL Indentation Devices as multiple devices for 3 or more samples: on request
PTL Indentation Devices according to DIN 72 551 Part 5&3.4.2 Fig. A.2: on request
BG5105線纜低溫沖擊、低溫卷繞、低溫拉伸試驗裝置成套設備
適用范圍:
本試驗機是本公司最新研制的的一款低溫拉伸、卷繞自動智能為一體式的試驗機,該設備采用了人機界面控制,智能化操作方便更簡單,并配有微型打印機,打印測試數據。本設備包括四臺設備:高低溫試驗箱,電動低溫拉伸試驗裝置,低溫卷繞試驗裝置,低溫沖擊試驗裝置
高低溫試驗箱是模擬高低溫環境,廣泛用于確定電工、電子產品對高低溫環境的適應性(特別是產品的電氣性能和機械性能的變化情況),也可用于檢查試樣耐受某些腐蝕的能力。
對應標準:
GB/T2951-2008主要技術指標:
低溫卷繞試驗裝置一般適用于外徑12.5mm及以下的圓形絕緣線芯及不能制備啞鈴試件的扇形絕緣線芯。若有關電纜產品標準中規定,試驗應在大尺寸絕緣線芯上進行。否則,大尺寸絕緣線芯應進行低溫拉伸試驗。
電動低溫拉伸試驗裝置適用于高分子材料,電線電纜,橡膠、塑料絕緣護套在0~-40℃/-60℃/-70℃環境下進行拉伸的試驗儀器,其結構和性能均滿足GB/T2951-2008標準要求。
低溫沖擊試驗裝置適用于各種聚氯乙烯護套電纜,而與絕緣線芯的絕緣類型無關。如果有關電纜產品標準有規定,也適用于無護套的電線、軟線和扁平軟線的聚乙烯絕緣。護套電纜的聚氯乙烯絕緣不直接進行低溫沖擊試驗。
u 低溫箱工作尺寸:500×600×500mm;
u 溫度范圍: -40℃/-60℃/-70℃~150℃;
u 溫度波動度: ±0.5℃ (空載時);
u 溫度偏差: ≤±2℃;
u 升降溫平均速率: 0.7℃~1.0℃/min (空載時);
u 時間設定范圍: 0~9999 小時;
u 拉伸裝置:電機:90W ,安裝于低溫箱內;
Ø 最大拉伸度:220mm ;
Ø 拉伸速度:20~30mm/min ;
Ø 夾頭型式:非自緊式;
Ø 試樣規格:Ⅰ、Ⅱ號啞鈴片;
Ø 數據顯示:直讀伸長率;
u 卷繞裝置:卷繞試樣直徑:Ф2.5~Ф12.5mm;
Ø 卷繞棒直徑:Ф4.0~Ф50mm共17支;
Ø 過線套:Ф1.2~Ф14.5mm共10種,各二件;
Ø 試樣纏繞圈數:2~10圈;
Ø 卷繞速度:5s/圈;
u 沖擊裝置:沖擊高度:100mm;
Ø 砝碼:100、200、300、400、500、600、750、1000、1250、1500g ;
Ø 本系列裝置全為不銹鋼制作;
Ø 本裝置可分為單組式與三組式;
u 外形尺寸:根據客戶的選型提供;
u 電源:AC 220V 50/60Hz 20A。
FRC系列交直流分壓器高壓試驗裝置是現場測量用的用儀器儀表,主要用于脈沖高壓,雷電高壓,工頻高壓的測量以及電力系統及電氣、電子設備制造部門工頻交流高電壓和直流高電壓的測量。
產品特征
1、精度高AC:0.1 DC:0.1
是高壓靜電電壓表的更新換代新型產品
2、讀數方便
FRC系列分壓器由高壓分壓器上端均壓罩為高壓端,可直接接入被測高壓,下端有用接地端,供接地使用,用用電纜連接高壓分壓器和低壓顯示儀表,并選擇相應的電壓和量限即可開始測量,讀數即為“kV”
3、安全可靠
FRC系列分壓器是由高壓測量部分和低壓顯示儀表構成。工作時高壓部分和低壓儀表分開,實施安全可靠
產品別稱
多功能交直流分壓器、交直流分壓器、交直流高壓測量裝置、高壓分壓器、阻容分壓器、分壓器、阻容式交直流分壓器、千伏電壓表、千伏表、
技術參數
準確度及高壓阻抗
電壓等 | AC/DC50kV | AC/DC100kV | AC/DC200kV | AC/DC300kV | |
分壓比 | 1000:1 | 1000:1 | 1000:1 | 1000:1 | |
阻 抗 | 200MΩ | 400MΩ | 800MΩ | 1200MΩ | |
精確度 | 直流值 | 1.0 | 1.0 | 1.0 | 1.0 |
交流值 | 1.5 | 1.5 | 1.5 | 1.5 | |
重 量 | 10kg | 15kg | 25kg | 35kg |
2、工作環境
溫度:0~40℃
濕度:≤85%RH
其他電壓等可根據客戶要求定制
更多交直流分壓器高壓試驗裝置信息:http://www.whhnlc.com/home/6
推薦詳情:直流高壓發生器 http://www.whhnlc.com/home/21 接地電阻測試儀 http://www.whhnlc.com/home/53
依據GB/T 328.25-2007《建筑防水卷材試驗方法 第25部分:瀝青和高分子防水卷材 抗靜態荷載》中第5.7條真空或壓力裝置對儀器的要求設計制造的。適用瀝青和高分子防水卷材以及其它防水卷材做抗靜態荷載穿刺或抗沖擊后,其穿透性能的檢測。具有結構簡單,操作方便的特點。
技術參數
1.壓力表測量范圍:0~25KPa
ZSY-27真空穿透試驗裝置
依據GB/T 328.25-2007《建筑防水卷材試驗方法 第25部分:瀝青和高分子防水卷材 抗靜態荷載》中第5.7條真空或壓力裝置對儀器的要求設計制造的。適用瀝青和高分子防水卷材以及其它防水卷材做抗靜態荷載穿刺或抗沖擊后,其穿透性能的檢測。具有結構簡單,操作方便的特點。
技術參數
1.壓力表測量范圍:0~25KPa
專業沖水裝置,IP5IP6沖水試驗裝置,手持式沖水試驗裝置 產品特點:
本產品是模擬淋水的環境試驗設備,主要是考核電工電子產品外殼和密封件在噴水試驗后和在試驗期間能否保證設備和元件良好的工作性能。本設備滿足GB/T4942.1-2006《旋轉電機整體結構的防護等級分級》
GB/T4942.2-1993《低壓電器外殼防護等級》
符合GB/T4942.2-1993中表4第5條款、第6條款要求,防護等級IPX5和IPX6
符合GB/T4942.1-2006中表5第5條款、第6條款要求,防護等級IP5X和IPX6
型號規格:
型號:IPX5/X6
IPX5,IPX6沖水裝置的技術規格 1、噴水口徑:IPX5為ø 6.3㎜ IPX6為ø 12.5 ㎜(附圖)
噴頭材質:304不銹鋼,IPX5、IPX6噴嘴螺紋聯接、快速更換
2、噴水水壓:30~100kpa 3、 噴水量: IPX5試驗噴水流量:12.5±0.625L/min
IPX6試驗噴水流量: 100±5L/min
4.噴嘴至試驗件外殼表面距離:2.5m~3m 5.沖水試驗裝置說明及組成: 裝置說明:本裝置按《GB4208-2008外殼防護等級IP代碼》中技術要求IP×5 ,IP×6第二特征數字5,6)設計制造。 防噴試驗時,可移動至任何一處適合場所防噴試驗,按所須要求調節好流量、壓力、時間及噴射范圍。即可進行試驗。 裝置組成: 試驗裝置由蓄水箱(500L)、加壓水泵、調減壓閥、流量調節器(2只)、壓力表、耐 壓水管、分流裝置及噴射支架電器控制箱等組成。 儲水箱:加厚型高級拉絲不銹鋼氬弧焊接制成。 噴射支架:不銹鋼精加工制成,符合GB4208外殼防護IP代碼技術要求。 6、沖水試驗裝置水壓控制系統: a、用流量計調節壓力大小 b、泄壓手動調節水閥 c、配備水過濾器 7、沖水試驗裝置符合標準:本設備是按GB/T4208-2008有關技術參數設計制作。
適用于檢驗將插頭從插座拔出所需要的最大力及單極插銷從插套組件拔出的所需要的最小力是否在標準規定的范圍內;
配置:二極10A、三極10A和16A試驗標準插頭各一個;
10A、16A試驗標準插銷各一個;
砝碼、夾緊裝置一套。